Which risk of bias tool should you use?
Your included studies are in, and before you combine their results you need to judge how far each can be trusted. The right tool depends mostly on study design, so a review with several designs may need several tools.
Updated
In brief
- Risk of bias is about systematic error in a result. Precision, applicability and reporting are separate questions.
- Use RoB 2 for randomized trials, ROBINS-I for non-randomized studies of interventions and ROBINS-E for exposures.
- For diagnostic accuracy studies, QUADAS-3 has replaced QUADAS-2.
- Don’t add item scores into a total. Report a judgement for each domain.
- Have two people assess each result independently, and carry the judgements into the synthesis and GRADE.
Quality assessment vs risk of bias
Risk of bias is the narrower idea. It’s the risk that a study’s result systematically overestimates or underestimates the true effect, and chapter 7 of the Cochrane Handbook speaks of risk because it’s usually impossible to know how far bias has affected a particular result.
Quality, as the authors of RoB 2 point out, can include study characteristics that aren’t inherently related to bias, such as performing a sample size calculation. Bias also differs from imprecision, which is random error and shows in the confidence interval, and from applicability to your question.
Reporting is separate again, and the original Cochrane tool left it out of scope. Information you need is often missing from published articles, and protocols, registers and study authors can fill some gaps.
Choosing a risk of bias tool by study design
Pick the tool that matches each included study’s design.
| Study design | Tool | Domains | Judgements |
|---|---|---|---|
| Randomized trial | RoB 2 | Randomization process; deviations from intended interventions; missing outcome data; measurement of the outcome; selection of the reported result | Low risk of bias, some concerns, high risk of bias |
| Cluster-randomized or crossover trial | RoB 2 variant for the design | As RoB 2. The cluster variant adds timing of identification and recruitment of participants | As RoB 2 |
| Non-randomized study of an intervention | ROBINS-I | Confounding; selection of participants into the study; classification of interventions; deviations from intended interventions; missing data; measurement of the outcome; selection of the reported result | Low, moderate, serious or critical risk of bias, or no information |
| Cohort study of an exposure | ROBINS-E | Confounding; measurement of the exposure; selection of participants into the study; post-exposure interventions; missing data; measurement of the outcome; selection of the reported result | Low risk of bias, some concerns, high risk of bias, very high risk of bias |
| Diagnostic test accuracy study | QUADAS-3 | Participants; index test; target condition; analysis | Low, high or insufficient information, for risk of bias and, in the first three domains, applicability |
| Cohort or case-control study | Newcastle-Ottawa Scale | Selection; comparability; exposure (case-control) or outcome (cohort) | Stars |
| Analytical cross-sectional study | JBI assessment of risk of bias for analytical cross-sectional studies | Eight questions grouped by type of validity and domain of bias | Yes, no, unclear or not applicable |
| Qualitative study | JBI checklist for qualitative research | Ten questions, half on congruity between philosophy, methodology, methods and interpretation | Yes, no or unclear |
| Systematic review | AMSTAR 2 or ROBIS | AMSTAR 2 has 16 items. ROBIS has four domains and an overall judgement | High, moderate, low or critically low confidence (AMSTAR 2). Low, high or unclear (ROBIS) |
Risk of bias tools by study design. Domain names drop their opening words, such as “Bias due to”.
Randomized trial
- Tool
- RoB 2
- Domains
- Randomization process; deviations from intended interventions; missing outcome data; measurement of the outcome; selection of the reported result
- Judgements
- Low risk of bias, some concerns, high risk of bias
Cluster-randomized or crossover trial
- Tool
- RoB 2 variant for the design
- Domains
- As RoB 2. The cluster variant adds timing of identification and recruitment of participants
- Judgements
- As RoB 2
Non-randomized study of an intervention
- Tool
- ROBINS-I
- Domains
- Confounding; selection of participants into the study; classification of interventions; deviations from intended interventions; missing data; measurement of the outcome; selection of the reported result
- Judgements
- Low, moderate, serious or critical risk of bias, or no information
Cohort study of an exposure
- Tool
- ROBINS-E
- Domains
- Confounding; measurement of the exposure; selection of participants into the study; post-exposure interventions; missing data; measurement of the outcome; selection of the reported result
- Judgements
- Low risk of bias, some concerns, high risk of bias, very high risk of bias
Diagnostic test accuracy study
- Tool
- QUADAS-3
- Domains
- Participants; index test; target condition; analysis
- Judgements
- Low, high or insufficient information, for risk of bias and, in the first three domains, applicability
Cohort or case-control study
- Tool
- Newcastle-Ottawa Scale
- Domains
- Selection; comparability; exposure (case-control) or outcome (cohort)
- Judgements
- Stars
Analytical cross-sectional study
- Tool
- JBI assessment of risk of bias for analytical cross-sectional studies
- Domains
- Eight questions grouped by type of validity and domain of bias
- Judgements
- Yes, no, unclear or not applicable
Qualitative study
- Tool
- JBI checklist for qualitative research
- Domains
- Ten questions, half on congruity between philosophy, methodology, methods and interpretation
- Judgements
- Yes, no or unclear
Systematic review
- Tool
- AMSTAR 2 or ROBIS
- Domains
- AMSTAR 2 has 16 items. ROBIS has four domains and an overall judgement
- Judgements
- High, moderate, low or critically low confidence (AMSTAR 2). Low, high or unclear (ROBIS)
For diagnostic accuracy, the developers now recommend QUADAS-3, published in February 2026, and say QUADAS-2 has been superseded. QUADAS-3 defines an ideal test accuracy trial for each synthesis question, then assesses each accuracy estimate separately.
To appraise systematic reviews, use AMSTAR 2 or ROBIS. AMSTAR 2 rates confidence from weaknesses in seven critical domains, which its authors call a suggestion. ROBIS judges concerns about study eligibility criteria, identification and selection of studies, data collection and study appraisal, and synthesis and findings.
RoB 2 for randomized trials
Cochrane recommends RoB 2 for randomized trials, though chapter 7 says the original Cochrane tool is acceptable for the time being. Each assessment covers one result, the effect on one outcome, because risk of bias can differ between outcomes and analyses.
Within each domain, chapter 8 has you answer signalling questions with yes, probably yes, probably no, no or no information. An algorithm proposes a judgement, which you can override with a reason. The overall judgement is the least favourable across domains, and some concerns in several domains can add up to high risk of bias. Decide first whether you’re interested in the effect of assignment to the intervention or of adhering to it, since that changes one domain.
Cluster-randomized and crossover trials have their own variants, described in chapter 23. The cluster version adds a domain on when participants were identified and recruited, and the crossover version addresses carry-over and period effects. On riskofbias.info, the current RoB 2 is dated 22 August 2019, the variants were revised on 18 March 2021, and the 2016 RoB 2.0 is archived.
Risk of bias tools for observational studies
For a non-randomized study of an intervention, use ROBINS-I. It treats each study as an attempt to emulate a hypothetical pragmatic randomized trial, the target trial. Low risk of bias means comparable to a well-performed randomized trial, so for the intended effects of an intervention the Handbook expects it only rarely, because of confounding. List the important confounding domains in your protocol.
ROBINS-I V2, a revised version dated 20 November 2025 for follow-up (cohort) studies, is still a draft and subject to change. It adds algorithms that propose judgements and drops the domain on deviations from intended interventions, leaving six.
For exposures, such as environmental, occupational or behavioural ones, use ROBINS-E. It currently covers only follow-up (cohort) studies, and variants for other designs, including case-control studies, are in development.
The Newcastle-Ottawa Scale, and why not to sum scores
The Newcastle-Ottawa Scale was developed to assess the quality of nonrandomised studies. Its developers’ page has versions for case-control and cohort studies, and none for cross-sectional studies. Studies earn stars for the selection of the study groups, their comparability, and the ascertainment of the exposure (case-control) or outcome (cohort).
A study gets at most one star per numbered item under selection and exposure or outcome, and up to two for comparability. Neither the scale nor its coding manual says how to turn stars into a rating such as good or poor.
Pitfall: Summing item scores into one number
The AMSTAR 2 authors write that the NOS “appears to lack sensitivity and is sometimes used to generate an overall score, something that is not recommended because it may disguise critical weaknesses in a review”. Cochrane moved away from quality scales after the choice of scale was shown to change a meta-analysis’s interpretation. Report a judgement for each domain, and reach any overall judgement by the tool’s own rule.
Cross-sectional and qualitative studies
JBI’s critical appraisal tools cover both, each tailored to its design. The tool for analytical cross-sectional studies was revised in 2026, and prevalence studies have their own checklist. The cross-sectional and qualitative tools both end with an overall appraisal of include, exclude or seek further info.
From assessment to synthesis and GRADE
Chapter 7 says it isn’t appropriate to present analyses while ignoring flaws found in the assessment. It describes four strategies, and your protocol should say which you’ll use:
- restrict the primary analysis to studies at low risk of bias, with sensitivity analyses that add the rest;
- present analyses stratified by risk of bias;
- present all studies with a narrative discussion, which the Handbook discourages when risks differ;
- adjust effect estimates for bias, which Cochrane doesn’t encourage.
Risk of bias is also one of the five GRADE domains for the certainty of a body of evidence, and chapter 14 maps the tools’ judgements onto it.
| Risk of bias judgement | GRADE study limitations |
|---|---|
| Low risk of bias | No limitation |
| Some concerns (RoB 2) | No limitation or serious limitation |
| High risk of bias (RoB 2) | Serious or very serious limitation |
| Critical risk of bias (ROBINS-I) | Extremely serious limitation |
Evidence from non-randomized studies assessed with ROBINS-I may start as high certainty, but should generally be downgraded by two levels for confounding and selection bias.
Two assessors, working independently
Cochrane requires at least two people to apply the tool independently to each result, with the process for resolving disagreements set in advance. Chapter 7 suggests piloting the tool on three to six papers, and doesn’t recommend kappa statistics, because exploring the reasons for each disagreement matters more.
Make every judgement traceable, since PRISMA 2020 asks you to present each included study’s assessment. Record where the information came from, down to its place in the document, and quote the report briefly where you can.
What to report: What to report
PRISMA 2020 item 11 asks for the risk of bias methods, including the tools, how many reviewers assessed each study, whether they worked independently and any automation tools. Item 18 asks for each included study’s assessment, and item 15 for how you assessed certainty.
Doing this in OtterSR
A review’s Risk of bias tab offers RoB 2 (effect of assignment), the ROBINS-I V2 draft, the Newcastle-Ottawa Scale and QUADAS-2, each with its citation and licence, or a checklist of your own that the AI can draft from one you paste. Auto-generate suggests a tool from the designs your criteria allow.
The AI answers each signalling question with the passages and pages it rests on. The tool’s algorithm suggests each domain’s judgement, and a person confirms it or chooses another, with a reason. Each study is assessed for one named outcome, and a second independent assessor isn’t built in yet. In Write, the toolbar inserts the traffic-light plot, the summary plot or a table of the confirmed judgements. See how it works and how to use OtterSR.
Here’s RoB 2 run on one open-access trial, saved as it came out. Open a domain to see each answer and the sentences it quotes.
A real run, saved as it came out
RoB 2 on one open-access trial
Procedural sedation and analgesia versus general anesthesia for hysteroscopic myomectomy (PROSECCO trial): A multicenter randomized controlled trial van der Meulen JF, Bongers MY, van der Zee LG, et al. PLoS Medicine 2023. DOI 10.1371/journal.pmed.1004323, PMC10754450. Open access under the Creative Commons Attribution License (CC BY), as the article states.
Outcome assessed: Complete resection of the fibroid(s), assessed on transvaginal ultrasonography 6 weeks after surgery (the primary outcome)
Run on 12 November 2026 through OtterSR’s own pipeline on a local copy of the app: GROBID read the PDF, and OtterSR’s default model (Otter-Mini) answered each signalling question that applied, with nobody editing the answers. Four questions weren’t sent to the model because their conditions weren’t met. It’s one example, run once, and not a measure of accuracy. We checked question 2.6 against the article, and the AI got it wrong (see domain D2). Nobody has checked the other answers against a published assessment of this trial. In the app, a person confirms or changes every answer and judgement, which is the step that catches a mistake like this one.
D1 · Risk of bias arising from the randomization processSuggested by the algorithm: Low risk of bias
1.1 Was the allocation sequence random?
AI answer: Yes
Sentence [50] reports that randomization used an internet-based program with random permuted block sizes of 2, 4, or 6, indicating a random allocation sequence.
“Randomization was performed by using an internet-based randomization program in a 1:1 ratio with random permuted blocks of sizes 2, 4, or 6 and was stratified by the surgical technique used (morcellation or resection).” (page 6)
1.2 Was the allocation sequence concealed until participants were enrolled and assigned to interventions?
AI answer: Yes
Sentence [50] states that randomization used an internet-based program, a remote allocation method consistent with the tool’s ‘Yes’ guidance. The report does not describe further concealment procedures, but the stated internet-based randomization supports this judgment.
“Randomization was performed by using an internet-based randomization program in a 1:1 ratio with random permuted blocks of sizes 2, 4, or 6 and was stratified by the surgical technique used (morcellation or resection).” (page 6)
1.3 Did baseline differences between intervention groups suggest a problem with the randomization process?
AI answer: No
The trial reports baseline characteristics for all randomized participants in Table 1, including age, BMI, parity, prior uterine surgery, hormonal medication use, fibroid number, type, and size; the reported group values appear broadly similar, with no substantial imbalance indicated (sentences [83], [98]-[108]). The randomization was 1:1, and 106 versus 103 participants were allocated, which is not a substantial group-size difference (sentences [50], [75]). Thus, the available baseline information does not suggest a problem with randomization.
“Randomization was performed by using an internet-based randomization program in a 1:1 ratio with random permuted blocks of sizes 2, 4, or 6 and was stratified by the surgical technique used (morcellation or resection).” (page 6)
“After written informed consent was obtained, 209 women were randomly allocated to hysteroscopic myomectomy under PSA (n = 106) or GA (n = 103) (Fig 1).” (page 6)
“Baseline characteristics of all women and fibroids (as examined by TVU) are presented in Table 1.” (page 7)
“Characteristic PSA N = 106 GA N = 103 Age, years (mean, sd) 45.1 (6.4) 45.0 (7.7) BMI (median, IQR) 24.7 (22.0-28.6)” (page 8)
“Parity (median, IQR) 1 (0-2) 1 (0-2) Previous uterine surgery 18 (17.0%)” (page 8)
“specification: hysteroscopic myomectomy 8/18 (44.4%) 14/24 (58.3%) other 10/18 (55.6%) 10/24 (41.7%)” (page 8)
“Use of hormonal medication at the time of surgery 52 (49.1%) 45 (43.7%)” (page 8)
“Reason for hysteroscopic myomectomy* abnormal uterine bleeding 101 (96.2%) 96 (93.2%) abdominal complaints 6 (5.7%) 9 (8.7%) subfertility 4 (3.8%) 5 (4.9%) other 1 (1.0%) 2 (1.9%) No. submucous myomas intended to be resected 119 113 one 93 (87.7%) 94 (91.3%) two 13 (12.3%)” (page 8)
“8 (7.8%) three 0 (0.0%) 1 (1.0%)” (page 8)
“Myoma type type 0 46 (39.3%) 56 (52.8%) type 1 71 (60.7%)” (page 8)
“Maximum size (diameter [mm]; mean, sd) 20.9 (6.4) 19.9 (6.8) Presence of additional fibroids that can't be resected hysteroscopically yes 36 (34.6%) 30 (29.1%) Percentages are column percentages based on the number of observations available.” (page 8)
“[Table 3 . Anesthetic complications.]” (page 10)
D2 · Risk of bias due to deviations from the intended interventions (effect of assignment to intervention)Suggested by the algorithm: High risk of bias
Reviewer’s check: With 2.6 corrected to Yes, RoB 2’s algorithm gives this domain Low risk, not High. The overall judgement stays High, because domain D3 is High.
2.1 Were participants aware of their assigned intervention during the trial?
AI answer: Yes
Participants were not blinded to their allocated treatment, as the article states that treating physicians and patients were not blinded (sentence [51]). Therefore, participants were aware of their assigned intervention.
“Treating physicians and patients were not blinded for the allocated treatment.” (page 6)
2.2 Were carers and people delivering the interventions aware of participants' assigned intervention during the trial?
AI answer: Yes
The trial states that treating physicians and patients were not blinded to the allocated treatment (sentence [51]). Since treating physicians delivered the interventions, carers and intervention providers were aware of assignment.
“Treating physicians and patients were not blinded for the allocated treatment.” (page 6)
2.3 If Y/PY/NI to 2.1 or 2.2: Were there deviations from the intended intervention that arose because of the trial context?
AI answer: No
The paper reports deviations from assigned anesthesia, including patients receiving the other anesthesia or withdrawing consent, but does not say these deviations arose because of trial recruitment, engagement, or other trial-context effects (Figure 1; sentences [77]-[80]). The reported reasons do not establish a trial-context cause, so there is no information to answer this question affirmatively or negatively.
“In the PSA group, 101 of 106 women (95.3%) received the allocated intervention.” (page 7)
“PSA was administered with propofol combined with alfentanil in 72% or remifentanil in 28% of women.” (page 7)
“In the GA group, 95 of 103 women (92.2%) received GA.” (page 7)
“Reasons for deviation are presented in Fig 1 .” (page 7)
“[Fig 1 .]” (page 7)
2.4 If Y/PY to 2.3: Were these deviations likely to have affected the outcome?
AI answer: Not applicable (not asked: its condition wasn’t met)
2.5 If Y/PY/NI to 2.4: Were these deviations from intended intervention balanced between groups?
AI answer: Not applicable (not asked: its condition wasn’t met)
2.6 Was an appropriate analysis used to estimate the effect of assignment to intervention?
AI answer: No
The primary-outcome analysis was not a full ITT analysis: the flow diagram reports 98 PSA and 89 GA participants analyzed, although 106 and 103 were randomized, and the text says outcome data were missing for 8 and 14 women, respectively (sentences [89]–[92]; Figure 1). The analysis also excluded randomized participants who did not undergo myomectomy or did not receive their assigned anesthesia, as specified in the Figure 1 caption; these are post-randomization exclusions, so the analysis is inappropriate for estimating the effect of assignment to intervention.
Reviewer’s check: This should be Yes. The Figure 1 caption the AI relied on defines the per-protocol population. The main analysis left out only the women with no 6-week ultrasound (106 − 8 = 98 and 103 − 14 = 89), and RoB 2’s guidance says that modified intention-to-treat analyses “excluding participants with missing outcome data should be considered appropriate”. Those missing results are judged in domain D3. With 2.6 as Yes, 2.7 isn’t asked.
“Data were analyzed according to the intention-to-treat (ITT) principle.” (page 6)
“Imputation of missing data was not used.” (page 6)
“For 8 women (7.5%) in the PSA group, the primary outcome (TVU at 6 weeks postsurgery) was missing.” (page 8)
“In the GA group, the TVU result was unavailable for 14 women (13.6%).” (page 8)
“Hysteroscopic resection was complete (as based on TVU) in 86/98 (87.8%) women under PSA and in 79/89 (88.8%) under GA (risk difference -1.01%; 95% CI -10.36 to 8.34).” (page 8)
“[Fig 1 .]” (page 7)
2.7 If N/PN/NI to 2.6: Was there potential for a substantial impact (on the result) of the failure to analyse participants in the group to which they were randomized?
AI answer: Yes
The primary-outcome analysis excluded participants without a 6-week TVU result: 8/106 in the PSA group and 14/103 in the GA group (sentences [89]–[90]). The ITT analysis therefore included 98 and 89 participants, respectively, rather than all 209 randomized participants (Table 2; Figure 1). These missing outcomes represent a substantial proportion, particularly in the GA group, and could have affected the estimated difference in complete resection; the reported result was 86/98 versus 79/89 (sentence [92]).
“After written informed consent was obtained, 209 women were randomly allocated to hysteroscopic myomectomy under PSA (n = 106) or GA (n = 103) (Fig 1).” (page 6)
“For 8 women (7.5%) in the PSA group, the primary outcome (TVU at 6 weeks postsurgery) was missing.” (page 8)
“In the GA group, the TVU result was unavailable for 14 women (13.6%).” (page 8)
“Hysteroscopic resection was complete (as based on TVU) in 86/98 (87.8%) women under PSA and in 79/89 (88.8%) under GA (risk difference -1.01%; 95% CI -10.36 to 8.34).” (page 8)
“[Table 4 .]” (page 10)
“[Fig 1 .]” (page 7)
D3 · Risk of bias due to missing outcome dataSuggested by the algorithm: High risk of bias
3.1 Were data for this outcome available for all, or nearly all, participants randomized?
AI answer: No
The primary outcome was missing for 8/106 participants in the PSA group and 14/103 in the GA group (sentences [89]–[90]), so outcome data were available for 187/209 randomized participants (89.5%). The report states that missing data were not imputed (sentence [55]); this is not nearly all participants, supporting No.
“Imputation of missing data was not used.” (page 6)
“After written informed consent was obtained, 209 women were randomly allocated to hysteroscopic myomectomy under PSA (n = 106) or GA (n = 103) (Fig 1).” (page 6)
“For 8 women (7.5%) in the PSA group, the primary outcome (TVU at 6 weeks postsurgery) was missing.” (page 8)
“In the GA group, the TVU result was unavailable for 14 women (13.6%).” (page 8)
“[Table 4 .]” (page 10)
“[Fig 1 .]” (page 7)
3.2 If N/PN/NI to 3.1: Is there evidence that the result was not biased by missing outcome data?
AI answer: No
The primary outcome was missing for 8 women in the PSA group and 14 in the GA group (sentences [89]–[90]). The authors state that missing data were not imputed (sentence [55]), and report no sensitivity analysis or other method correcting for bias from missing primary-outcome data; therefore, there is no evidence that the result was not biased by missing outcome data.
“Imputation of missing data was not used.” (page 6)
“For 8 women (7.5%) in the PSA group, the primary outcome (TVU at 6 weeks postsurgery) was missing.” (page 8)
“In the GA group, the TVU result was unavailable for 14 women (13.6%).” (page 8)
“[Table 4 .]” (page 10)
“[Fig 1 .]” (page 7)
3.3 If N/PN to 3.2: Could missingness in the outcome depend on its true value?
AI answer: Yes
The primary outcome was complete resection assessed by TVU at 6 weeks (sentences [38]–[39]). Outcome data were missing for 8 women in the PSA group and 14 in the GA group, and the article reports no imputation ([55], [89]–[90]). It does not give reasons for these missing TVU results; because missingness could be related to participants’ health status or outcome, dependence on the true outcome cannot be ruled out.
“The primary outcome was the percentage of complete resections, evaluated by transvaginal ultrasonography (TVU) (contrast sonography when TVU was inconclusive) 6 weeks postoperatively.” (page 5)
“Complete resection was defined as the absence of an intracavitary remnant of the fibroid (s) resected during hysteroscopic myomectomy.” (page 5)
“Imputation of missing data was not used.” (page 6)
“For 8 women (7.5%) in the PSA group, the primary outcome (TVU at 6 weeks postsurgery) was missing.” (page 8)
“In the GA group, the TVU result was unavailable for 14 women (13.6%).” (page 8)
“[Fig 1 .]” (page 7)
3.4 If Y/PY/NI to 3.3: Is it likely that missingness in the outcome depended on its true value?
AI answer: Probably yes
The primary outcome was missing for 8/106 women in the PSA group and 14/103 in the GA group (sentences [89]–[90]), so missingness differed between groups. The article does not report reasons for these missing ultrasound outcomes or evidence that missingness was related to the true resection result; the imbalance raises concern but does not establish that dependence was likely.
“The primary outcome was the percentage of complete resections, evaluated by transvaginal ultrasonography (TVU) (contrast sonography when TVU was inconclusive) 6 weeks postoperatively.” (page 5)
“For 8 women (7.5%) in the PSA group, the primary outcome (TVU at 6 weeks postsurgery) was missing.” (page 8)
“In the GA group, the TVU result was unavailable for 14 women (13.6%).” (page 8)
“Among these women, 7/8 in the PSA group and 8/14 in the GA group did complete the digital questionnaires and could still be included in analyses for secondary outcomes (Fig 1).” (page 8)
“Imputation of missing data was not used.” (page 6)
“[Table 4 .]” (page 10)
“[Fig 1 .]” (page 7)
D4 · Risk of bias in measurement of the outcomeSuggested by the algorithm: Low risk of bias
4.1 Was the method of measuring the outcome inappropriate?
AI answer: Probably no
The primary outcome was complete resection assessed by transvaginal ultrasonography at 6 weeks, with contrast sonography used when TVU was inconclusive (sentences [38]-[40]). Although the authors later noted that TVU was not always accurate for evaluating completeness, particularly when multiple fibroids were present (sentences [187]-[189]), this indicates limitations in accuracy rather than that the measurement method was clearly inappropriate; the assessment was also performed by a blinded experienced sonographer or gynecologist (sentences [40]-[42]).
“The primary outcome was the percentage of complete resections, evaluated by transvaginal ultrasonography (TVU) (contrast sonography when TVU was inconclusive) 6 weeks postoperatively.” (page 5)
“Complete resection was defined as the absence of an intracavitary remnant of the fibroid (s) resected during hysteroscopic myomectomy.” (page 5)
“TVU was performed by an experienced sonographer or gynecologist blinded for the treatment arm and the surgery outcome.” (page 5)
“If it was concluded that resection was incomplete based on TVU, the images were adjudicated by an independent review committee, blinded for the type of anesthesia and the surgeon's judgment on completeness during the procedure.” (page 5)
“When applicable, the result of the TVU was recorded as complete after adjudication.” (page 5)
“However, it turned out that TVU after 6 weeks was not always accurate to evaluate completeness and success of the procedure.” (page 12)
“For example, when multiple fibroids were present, it was difficult for a blinded sonographer to assess if there was a remnant of a resected fibroid or if these fibroids had not been resected and were still expected to be present.” (page 12)
“Also, the presence of a small remnant lesion without any clinical consequences does not necessarily mean that the procedure was unsuccessful from a patient perspective.” (page 12)
4.2 Could measurement or ascertainment of the outcome have differed between intervention groups?
AI answer: No
The primary outcome was assessed by transvaginal ultrasonography 6 weeks after surgery, with contrast sonography used when TVU was inconclusive (sentences [38]-[39]). The same assessment timing and method applied to both groups, and the sonographer was blinded to treatment allocation (sentences [40], [52]); the article reports no group-specific difference in outcome ascertainment.
“The primary outcome was the percentage of complete resections, evaluated by transvaginal ultrasonography (TVU) (contrast sonography when TVU was inconclusive) 6 weeks postoperatively.” (page 5)
“Complete resection was defined as the absence of an intracavitary remnant of the fibroid (s) resected during hysteroscopic myomectomy.” (page 5)
“TVU was performed by an experienced sonographer or gynecologist blinded for the treatment arm and the surgery outcome.” (page 5)
“However, the sonographer assessing the primary outcome 6 weeks postoperatively was blinded for the treatment arm and the surgical outcome.” (page 6)
4.3 If N/PN/NI to 4.1 and 4.2: Were outcome assessors aware of the intervention received by study participants?
AI answer: No
The primary outcome was assessed by transvaginal ultrasonography, and the paper states that the sonographer assessing it was blinded to the treatment arm and surgical outcome (sentences [38], [40], and [52]). Thus, outcome assessors were not aware of the intervention received.
“The primary outcome was the percentage of complete resections, evaluated by transvaginal ultrasonography (TVU) (contrast sonography when TVU was inconclusive) 6 weeks postoperatively.” (page 5)
“TVU was performed by an experienced sonographer or gynecologist blinded for the treatment arm and the surgery outcome.” (page 5)
“However, the sonographer assessing the primary outcome 6 weeks postoperatively was blinded for the treatment arm and the surgical outcome.” (page 6)
4.4 If Y/PY/NI to 4.3: Could assessment of the outcome have been influenced by knowledge of intervention received?
AI answer: Not applicable (not asked: its condition wasn’t met)
4.5 If Y/PY/NI to 4.4: Is it likely that assessment of the outcome was influenced by knowledge of intervention received?
AI answer: Not applicable (not asked: its condition wasn’t met)
D5 · Risk of bias in selection of the reported resultSuggested by the algorithm: Some concerns
5.1 Were the data that produced this result analysed in accordance with a pre-specified analysis plan that was finalized before unblinded outcome data were available for analysis?
AI answer: Yes
The primary outcome and its analysis approach were specified in the Methods: completeness was assessed by TVU at 6 weeks, and the statistical analysis plan is referenced in sentence [70]. The report says the protocol was published and no major protocol changes were made (sentences [23]-[24]), but it does not establish when the analysis plan was finalized relative to availability of unblinded outcome data; this supports probably yes rather than an unequivocal yes.
“The full study protocol was published in 2019 [32].” (page 4)
“During the course of the study, no major changes to the study protocol were made.” (page 4)
“The primary outcome was the percentage of complete resections, evaluated by transvaginal ultrasonography (TVU) (contrast sonography when TVU was inconclusive) 6 weeks postoperatively.” (page 5)
“Complete resection was defined as the absence of an intracavitary remnant of the fibroid (s) resected during hysteroscopic myomectomy.” (page 5)
“Data were analyzed according to the intention-to-treat (ITT) principle.” (page 6)
“The primary outcome was evaluated by estimating the risk difference between both treatment arms, with adjustment for stratification factor (resection technique).” (page 6)
“A Farrington-Manning test was used to determine the p-value for noninferiority.” (page 6)
“Details on the statistical analyses can be found in the statistical analysis plan (Statistical Analysis Plan in S1 Text).” (page 6)
Is the numerical result being assessed likely to have been selected, on the basis of the results, from...
5.2 ... multiple eligible outcome measurements (e.g. scales, definitions, time points) within the outcome domain?
AI answer: No information
The primary outcome is complete resection assessed by TVU at 6 weeks, with a definition based on absence of an intracavitary remnant (sentences [38]-[39]). The article says the protocol was published and no major protocol changes were made, but does not provide enough detail about intended alternative eligible measurements within this outcome domain to determine whether all were reported (sentences [23]-[25]); therefore, there is no information to assess selection among multiple measurements.
“The full study protocol was published in 2019 [32].” (page 4)
“During the course of the study, no major changes to the study protocol were made.” (page 4)
“The primary outcome was the percentage of complete resections, evaluated by transvaginal ultrasonography (TVU) (contrast sonography when TVU was inconclusive) 6 weeks postoperatively.” (page 5)
“Complete resection was defined as the absence of an intracavitary remnant of the fibroid (s) resected during hysteroscopic myomectomy.” (page 5)
Is the numerical result being assessed likely to have been selected, on the basis of the results, from...
5.3 ... multiple eligible analyses of the data?
AI answer: No information
The primary outcome was complete resection assessed by TVU at 6 weeks (sentences [38]–[39]). The paper says the statistical analysis plan contains analysis details (sentence [70]), but does not provide enough detail here to establish whether all eligible analysis methods were prespecified or whether multiple analyses were selectively reported; therefore, the appropriate choice is No information.
“The primary outcome was the percentage of complete resections, evaluated by transvaginal ultrasonography (TVU) (contrast sonography when TVU was inconclusive) 6 weeks postoperatively.” (page 5)
“Complete resection was defined as the absence of an intracavitary remnant of the fibroid (s) resected during hysteroscopic myomectomy.” (page 5)
“Imputation of missing data was not used.” (page 6)
“The primary outcome was evaluated by estimating the risk difference between both treatment arms, with adjustment for stratification factor (resection technique).” (page 6)
“A Farrington-Manning test was used to determine the p-value for noninferiority.” (page 6)
“For adjustment of stratification factor, a generalized linear model was used with identity link and binomial distribution where the stratification factor was used as a covariable.” (page 6)
“Details on the statistical analyses can be found in the statistical analysis plan (Statistical Analysis Plan in S1 Text).” (page 6)
“[Table 4 .]” (page 10)
Higgins JPT, Savović J, Page MJ, Sterne JAC (editors), on behalf of the RoB2 Development Group. Revised Cochrane risk-of-bias tool for randomized trials (RoB 2). 22 August 2019. This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. The signalling questions are quoted unchanged. The trial’s passages are quoted from the article under its CC BY licence.
Run this on your own PDFs. In a review you confirm or change each judgement, with a reason.
Create an account to run this on your own PDFsFree tools for this step
- Risk of bias traffic light and summary plot generatorUse this when you’ve judged risk of bias and need the traffic-light and summary figures for your paper, without installing R.
- Newcastle-Ottawa Scale calculatorUse this when you’re appraising cohort or case-control studies with the Newcastle-Ottawa Scale and want the stars per domain.
- GRADE summary of findings tableUse this when you’ve rated the certainty of each outcome with GRADE and need the summary of findings table, with absolute effects per 1000.
Related guides
- How to rate the certainty of evidence with GRADEHow GRADE rates the certainty of evidence per outcome: four levels, five reasons to rate down, three to rate up, and what goes in a summary of findings table.
- The hierarchy of evidence: the evidence pyramid, its critics and where systematic reviews sitThe hierarchy of evidence explained: the evidence pyramid, levels of evidence for each type of question, GRADE, and why systematic reviews moved off the top.
- How to design a data extraction formHow to design a data extraction form for a systematic review: which fields to collect, piloting, two extractors, and recording where each value came from.
Sources
- Boutron I, Page MJ, Higgins JP, Altman DG, Lundh A, Hróbjartsson A. Chapter 7: Considering bias and conflicts of interest among the included studies [last updated August 2022]. In: Higgins JP, Thomas J, Chandler J, et al (editors). Cochrane Handbook for Systematic Reviews of Interventions version 6.5. Cochrane, 2024. https://www.cochrane.org/authors/handbooks-and-manuals/handbook/current/chapter-07
- Sterne JAC, Savović J, Page MJ, et al. RoB 2: a revised tool for assessing risk of bias in randomised trials. BMJ 2019;366:l4898. https://doi.org/10.1136/bmj.l4898
- QUADAS-3 tool (version 1.2) and overview. QUADAS team, Population Health Sciences, Bristol Medical School, University of Bristol. https://www.bristol.ac.uk/population-health-sciences/projects/quadas/quadas-3/quadas-3-tool/
- QUADAS-2 (previous version, superseded by QUADAS-3). QUADAS team, Population Health Sciences, Bristol Medical School, University of Bristol. https://www.bristol.ac.uk/population-health-sciences/projects/quadas/history/quadas-2/
- Shea BJ, Reeves BC, Wells G, et al. AMSTAR 2: a critical appraisal tool for systematic reviews that include randomised or non-randomised studies of healthcare interventions, or both. BMJ 2017;358:j4008. https://pmc.ncbi.nlm.nih.gov/articles/PMC5833365/
- Whiting P, Savović J, Higgins JPT, et al. ROBIS: a new tool to assess risk of bias in systematic reviews was developed. Journal of Clinical Epidemiology 2016;69:225–34. https://pmc.ncbi.nlm.nih.gov/articles/PMC4687950/
- Higgins JP, Savović J, Page MJ, Elbers RG, Sterne JAC. Chapter 8: Assessing risk of bias in a randomized trial [last updated October 2019]. In: Higgins JP, Thomas J, Chandler J, et al (editors). Cochrane Handbook for Systematic Reviews of Interventions version 6.5. Cochrane, 2024. https://www.cochrane.org/authors/handbooks-and-manuals/handbook/current/chapter-08
- Higgins JP, Eldridge S, Li T. Chapter 23: Including variants on randomized trials [last updated October 2019]. In: Higgins JP, Thomas J, Chandler J, et al (editors). Cochrane Handbook for Systematic Reviews of Interventions version 6.5. Cochrane, 2024. https://www.cochrane.org/authors/handbooks-and-manuals/handbook/current/chapter-23
- RoB 2 tool: a revised tool to assess risk of bias in randomized trials, with variants for cluster-randomized and crossover trials. riskofbias.info. https://www.riskofbias.info/welcome/rob-2-0-tool
- Sterne JA, Hernán MA, Reeves BC, et al. ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions. BMJ 2016;355:i4919. https://pmc.ncbi.nlm.nih.gov/articles/PMC5062054/
- Sterne JAC, Hernán MA, McAleenan A, Reeves BC, Higgins JP. Chapter 25: Assessing risk of bias in a non-randomized study [last updated October 2019]. In: Higgins JP, Thomas J, Chandler J, et al (editors). Cochrane Handbook for Systematic Reviews of Interventions version 6.5. Cochrane, 2024. https://www.cochrane.org/authors/handbooks-and-manuals/handbook/current/chapter-25
- ROBINS-I V2: Risk Of Bias In Non-randomized Studies – of Interventions, Version 2 (revised draft, 20 November 2025). riskofbias.info. https://www.riskofbias.info/welcome/robins-i-v2
- Higgins JPT, Morgan RL, Rooney AA, et al. A tool to assess risk of bias in non-randomized follow-up studies of exposure effects (ROBINS-E). Environment International 2024;186:108602. https://doi.org/10.1016/j.envint.2024.108602
- Wells GA, Shea B, O’Connell D, et al. The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomised studies in meta-analyses. Ottawa Hospital Research Institute. https://ohri.ca/en/who-we-are/core-facilities-and-platforms/ottawa-methods-centre/newcastle-ottawa-scale
- JBI critical appraisal tools, including the assessment of risk of bias for analytical cross-sectional studies (2026) and the checklist for qualitative research. JBI. https://jbi.global/critical-appraisal-tools
- Schünemann HJ, Higgins JP, Vist GE, et al. Chapter 14: Completing ‘Summary of findings’ tables and grading the certainty of the evidence [last updated August 2023]. In: Higgins JP, Thomas J, Chandler J, et al (editors). Cochrane Handbook for Systematic Reviews of Interventions version 6.5. Cochrane, 2024. https://www.cochrane.org/authors/handbooks-and-manuals/handbook/current/chapter-14
- Page MJ, McKenzie JE, Bossuyt PM, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ 2021;372:n71. https://doi.org/10.1136/bmj.n71